Rapid Screening & Early Detection with COVID‐19 Nucleic Acid Detection Kit & iPonatic

Rapid Screening & Early Detection with COVID‐19 Nucleic Acid Detection Kit & iPonatic

COVID‐19 Nucleic Acid Detection Kit ‐A reagent that combines three genetic loci of the COVID‐19 with fluorescent PCR and multiplex PCR, by Sansure

Table of Contents

Product Features

  • Rapid screening and fast reporting: 10 minutes preparation and 30 minutes analyzing time, with iPonatic portable molecular workstation
  • High sensitivity: 200 copies/ml
  • Early detection during latent period
  • Easy Setup and Specially Designed for: 
    • Port Health for Port Authority & Border Control Checkpoint, .e.g International Airport, High Speed Rail Station, Land Border, Cruise Terminal
    • Provisional Quarantine Zone
    • Clinic
    • Transportable & Mobile Environment
    • Area without Full Diagnostic Laboratory access
    • Hospital
    • Cost effective for on‐site, limited quantity diagnostic need, specially designed for locations where laboratory technician may not be available
    • Applicable specimen type
        • Pharyngeal swab
        • Bronchoalveolar Wash
        • Sputum

      Approved by National Medical Products Administration

      (NMPA/CFDA), TFDA & US FDA (EUA)

    • Easy operation & streamline workflow: no heating, tube replacement, nucleic acid extraction, and amplification detection can be achieved in a simple step.
    • The pathogen is inactivated after sampling and reach a high level of biological safety.
    • The housekeeping gene and internal standard are monitored throughout to ensure the accuracy of the test results.

Competitive Advantage

RNA one‐step nucleic acid extraction free technology

a unique nucleic acid release agent, which can rapidly analyse pathogens at room temperature and inactivate pathogens to reduce bio‐safety hazards. Without boiling and tube changing, rapid extraction of sample nucleic acid can be achieved through a simple operation. It is the only product of all manufacturers that does not need to be heated or cracked by boiling.

Higher sensitivity

200 copies/ml. while other certified products were 1000 copies/ml.

Internal calibration and standardized whole‐process monitoring

endogenous housekeeper gene monitoring is adopted for the whole process, including sampling, testing, and other processes, to better avoid false‐negative results. There is no internal calibration in other licensed products.

Fast reporting time

Pre‐processing of 96 samples of nucleic acid was completed by the one‐step method of RNA in 30 minutes, and the results were reported within 2 hours. The shortest extraction time in all manufacturers.

Diversified extraction and matching methods

The reagent can match the onestep method, magnetic bead method or other manufacturers’ extraction methods, and the instrument can match iPonatic and Natch CS.

Detecting targets

National health council general office issued the new coronavirus pneumonia infection prevention and control program (second edition) “pointed out that for nucleic acid detection method, the novel coronavirus genome open reading code box 1 a/b 1 ab (ORF) and core‐shell protein N gene, the same specimens new coronavirus in the two target specificity of real‐time fluorescent RT‐PCR test results for positive can be confirmed. Therefore, the nucleic acid detection kit only needs to cover these two targets to meet the detection needs.

Optional Full Laboratory Solution

With COVID‐19 kit, Natch CS fully automated extraction system and Slan 96 PCR, high degree of automation and high detection flux: among the mainstream manufacturers, Some do not have a fully automatic nucleic acid extraction instrument, so it cannot realize highthroughput automatic detection. In the automatic manufacturers, Sansure automatic extraction speed is the fastest, can achieve 1 person 1 machine 1‐day detection of 1000 people. while other products are unable to reach.

Portable Molecular Workstation ( iPonatic) Installation Guide

Portable Molecular Workstation ( iPonatic) Installation Guide 

EASY>SAFE>PORTABLE 

With the help of the Portable Molecular Workstation healthcare workers will be able to get results whether patients have symptoms or not. 

Molecular diagnosis, as the most technical subdivision of IVD, has developed rapidly in recent years. On the other hand, POCT, with the characteristics of real-time test, has been widely concerned and developed rapidly. 

When molecular diagnosis is combined with POCT, it means that gene detection can also have the characteristics of real-time detection, which can achieve convenient sampling and timely detection. 

iPonatic POCT mobile molecular diagnosis system aims to subvert the traditional mode and bring precision medicine into thousands of households. It can provide quick and convenient diagnosis results for clinical emergency, health management, military safety, biological emergency and other fields. 

Portable Molecular Workstation ( iPonatic) Operation

Simple, Easy and Precise Operation of the Portable molecular workstation :-

  • Place the pipette tips in the correct position of the cartridge 
  • Remove the 4-tube strips cover and place it in the correct position of the cartridge 
  • Place the flat PCR tube in the correct position of the cartridge and open the lid. 
  • Use a pasteur to transfer the sample to sample well of the 4-tube strip. 
  • Put the prepared catridge into the iponatic. 
  • Click the experiment task, enter the name and select the method. Then click Submit and run. 
  • In 2-3 minutes, carefully take out the catrdige when the extraction is completed. Cap the lid, discard the pipette tip and 4-tube strip. 
  • Mix the tube 
  • Mark the tube 
  • Centrifuge the PCR plate 
  • Make sure the liquid has been centrifuged to the bottom of the tube. 
  • Insert the PCR tube into the PCR module 

Click [OK} 

  • Jump into the amplification interface. The whole process to be done in 42.5 minutes. 

Click [OK] 

  • Click to search in reverse order 
  • Select the name of the current experiment 
  • Click [Calculate] the data normalize and display amplification curve. 
  • Click [Print] and the device will print the report.

Portable Molecular Workstation ( iPonatic) Easy Working Process

With the help of the Portable Molecular Workstation healthcare workers will be able to get results whether patients have symptoms or not. 

Molecular diagnosis, as the most technical subdivision of IVD, has developed rapidly in recent years. 

On the other hand, POCT, with the characteristics of real-time test, has been widely concerned and developed rapidly. When molecular diagnosis is combined with POCT, it means that gene detection can also have the characteristics of real-time detection, which can achieve convenient sampling and timely detection. 

iPonatic POCT mobile molecular diagnosis system aims to subvert the traditional mode and bring precision medicine into thousands of households. 

It can provide quick and convenient diagnosis results for clinical emergency, health management, military safety, biological emergency and other fields.

Sansure Company BCompany CCompany D
CertificateCFDA / TFDACFDACFDACFDA
Detection MethodPCR-Fluorescence ProbingPCR-Fluorescence ProbingPCR-Fluorescence ProbingPCR-Fluorescence Probing
Sample Type Pharyngeal swabs and alveolar lavage samplesPharyngeal swabs, sputumNasopharyngeal swab, sputumPharyngeal swabs and alveolar lavage sample
Target GeneORFlab and N geneORFlab gene N geneORFlab gene N geneORFlab
Sensitivity200 copies/mL1000 copies/mL1000 copies/mL1000 copies/mL
Amplification Time30 min100 min80 min120 min
Internal ControlEndogenous internal controlEndogenous internal controlInternal controlInternal control
Validity6month6month6month6month
Specification24 test/kit24/48/96 test/kit50 test/kit50 test/kit
FeaturesOne Step fast release time, quick/easiest operation, 30-40 Minutes to report result. Highest Sensitivity 3. Endogenous internal control monitor sampling.extration and amplificationRNA reverse transcription time and amplification time is short complicated and long extraction time:Low sensitivity:Non-endogenous internal control cannot monitor sampling accuracy.RNA reverse transcription time and amplification time is short complicated and long extraction time:Low sensitivity:Non-endogenous internal control cannot monitor sampling accuracy.Only 1 target gene, Easy .complicated and long extraction time: More than 4 hours in all : Low sensitivity, Non endogenous internal control, cannot monitor sampling accuracy.
For any further information, query or pricing , kindly contact sinodia@sinodiamedical.com or 
call/whatsapp +86 138 1679 1882

About Mozocare